ATEX - Coriolis Meter, ALCM

           
ALSOINC-FX Mass Flow Meter
SmartMeasurement's ALCM coriolis mass flowmeters use two tubes in a parallel arrangement which are rotated at their resonant frequency by coils. Any mass flow passsing through the tubes will generate coriolis forces which appear whenever a mass moves radially in a rotating system. The forces have opposite effects on the inlet and outlet side, deforming each pipe by a minor amount. The excursion of the pipes is detected by the inlet and outlet-side sensors. The phase shift between the rotational frequencies of both pipes is directly proportional to the mass flow rate and the resonant frequency of both pipes changes in accordance with the density of the fluid media. This effect allows for measurement of the density. Using only one sensor, both density and temperature measurements may be performed. The extent of deformation of the pipes is temperature-dependent. Therefore, the temperature is measured for compensation purposes. Using only one primary sensor, values including mass flow, density, and temperature may be measured. The ALCM's microprocessor-based circuitry allows for conversions such as volumetric flow and % concentration to be calculated.

 Body (ALCM 00300 to ALCM 03000)Flow
Process ConnectionsFemale threads, G½" adapters for flanges (ANSI and DIN), dairy or tri-clamp®
Operating pressuremax. 5000 psig (350 bar)
Process temperatureup to 260 °F (125°C)
MaterialSS as per DIN 1.4571 (AISI 316 Ti)
Repeatability0.33% for liquid, 0.5% for gas, 0.83% for insertion
Housing protectonIP67
Electrical connection9-pin flange plug - compact version with integral transmitter
Max cable length100' (30 M) beween tranducer and transmitter
Ex-protectionEX II 2G EEx ib IIC T2-T4
Housing protectionIP65; IP67; IP68
Ex-protectionExid ⅡB T4; Exib ⅡC T 4
WeightALCM 00300 and 03000: 11-22 lbs (5-10 kg)
ALCM 06000 and 60000: 22-88 lbs (10-40 kg)
Flowbody (ALCM 06000 to ALCM 6000)
Process ConnectionsFlanges acc. EN 1092, ANSI B16.5, DIN2512
Nominal pressurePN 40, ANSI 150 / 300 lbs
Process temperature-40°F to +356°F ( -40°C to +180°C)
Ambient temperature-40°F to +140°F (-40°C to +60°C)
Enclosure protectionNEMA 4X (IP 65) (EN60529)
MaterialsFlow tubes, splitter flanges: 1.4404(316 L)/1.4571(316 Ti)
Housing materialCast iron
Ex-protectionEX II 2G EEx ib IIC T2-T4
 
Transmitter
LCD Display(illuminated)2-line alpha numerical, measured values & parameter settings, 2x 20 characters (2.4X 4.7 mm)
ProgrammingVia front keypad
Supply voltage24 VDC, ±15%
Power ConsumptionMax. 2 W
InterfaceRS-485
Weights3.3 lbs (1.5 kg) wall mount, 2.2 lbs (1 kg) panel mount
Housing Wall & PanelPlastic with transparent cover
Operating temperature32 to 122 °F (0 to 50 °C)
Ex protectionEX II (2) G (Eex ib) IIC
Temperature drift0.05% per 10 K load (Load>10 k)
Voltage outputstwo 0-5VDC, resolution: 12 bits, linearity ±0.05% final
Current outputs(1) 0/4-20mA, active, galvanically free, 12 bits resolution with linearity: ±0.05% of final value, Load ≤ 800 Ω scaled output of flow rate, or job total, density or temperature
Pulse outputsProportional to flow rate, 8-5 kHz, adjustable via jumper, push/pull: Imax-0mA open collector: Vce ≤ 30V, Ice ≤ 50 mA.
Switch outputsadjustable via jumper; push/pull: Imax 20mA. Open Collector: Vce ≤ 30V, Ice ≤ 50 mA, 1 or 2 job total, fault or rate or cycle
Switch inputspassive "on" >4VDC, "off" <1VDC; total, reset,& offset